Campo-equipment BLAZE 800 D/G Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 50
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com
WARNING: TURN OFF THE FUEL SUPPLIES AND POWER BEFORE PERFORMING SERVICE
WORK. THE 208V/240V CIRCUIT IS A POTENTIAL ELECTROCUTION HAZARD.
THE HEAT EXCHANGER CAN NOW BE CLEANED ENTIRELY FROM THE CLEAN-OUT PORTS AND THE FLUE
PIPE CONNECTION.
HEAT EXCHANGER CLEANING PROCEDURE
1.) REMOVE HEATER BOX PANELS
2.) REMOVE EASY ACCESS PANELS LOCATED ON HEAT EXCHANGER
3.) REMOVE BAFFLES FROM SECONDARIES AND CLEAN
4.) SHOVE FLEXIBLE BRUSH VIA ACCESS PANELS AND CLEAN THOROUGHLY
5.) SHOVE FLEXIBLE VACUUM VIA ACCESS PANELS AND VACUUM THOROUGHLY
HEAT EXCHANGER REASSEMBLY AFTER CLEANUP
1.) CLOSE EASY ACCESS PANELS ON HEAT EXCHANGER
2.) CLOSE HEATER BOX PANELS
COMBUSTION AIR ADJUSTMENTS
BLAZE 800 D/G
SPECIFICATIONS
BLAZE 800G-
BECKETT (NG/LP)
BLAZE 800D-
BECKETT (OIL)
Gas Conversion
RemoveOrificeas
perinstructions
foundinmanual.
Propaneorificepart
#3246707U,Oring
part#3226409U,
restrictorinside
diameter0.482
N/A
Manifold pressure “W.C.
3
N/A
Minimum/Maximum
Supply Pressure “W.C.
3/14
N/A
Nozzle
N/A 4.5 GPH X 60 B
Vue de la page 15